Versapak medical transport bags are manufactured with protective, padded insulation to provide hospitals, laboratories and other medical facilities with a safe and convenient way to transport temperature sensitive blood and laboratory samples.

Our medical transport bags have been tested at various ambient temperatures and can maintain a temperature of 2-8°C for extended periods of time when used in conjunction with cooling elements or cold packs. When used with a PCM battery, our blood transport bags can maintain a temperature of 15-25°C for an extended period of time.

The Versapak medical transport bags listed below have undergone rigorous testing and inspection throughout the manufacturing process. The thermal properties have been certified by the globally recognized testing body TÜV SÜD Product Service GmbH.

Labortasche PYB -Transport von Proben - Klein (English) mit Icecatch

We have tested our products extensively with two types of cooling elements and under different environmental conditions. The following tables provide an overview of the performance of each transport bag under the specified conditions:

Versapak medical transport bag with ICECATCH cooling element Solid Insulated Cool tested to maintain a temperature of 2-8 °C

Article Sample material (liters) (prepared to +4 °C) ICECATCH cooling element in grams (prepared to -18 °C) Insert (unprinted, insulated side in contact with contents) Ambient temperature Maintain temperature for
Versapak transport bag for blood, small (BLTD1) 2 x 0.5 liters of water 2 x 500g One at the bottom and one at the top. 21°C
30°C
21 hrs 29 min
18 hrs 12 min
Versapak transport bag for blood, large (BLTD2) 6 x 0.5 liters of water 3 x 500g All 3 on top. 21°C
30°C
28 hrs 43 min
17 hrs 20 min
Versapak insulated medical transport bag, small (PYTB1) 4 x 0.5 liters of water 2 x 500g One at the bottom and one at the top. 21°C
30°C
17 hrs 23 min
12 hrs 47 min
Versapak insulated medical transport bag, medium (PYTB2) 12 x 0.5 liters of water 2 x 500g + 1 x 1100g 2 x 500g on the sides and 1 x 1100g on top. 21°C
30°C
40°C
29 hrs 48 min
14 hrs 52 min
8 hrs 34 min
Versapak insulated medical transport bag, large (PYTB3) 16 x 0.5 liters of water 2 x 500g + 2 x 1100g 2 x 500g on the sides and 2 x 1100g on top. 21°C
30°C
31 hrs 25 min
15 hrs 55 min

Versapak medical transport bag with cold packs and thermal barriers tested to maintain a temperature of 2-8 °C

Article Sample material (liters) (prepared to +4 °C) Cold pack in grams (prepared to -18 °C) Thermal barrier (prepared to +4 °C) Ambient temperature Maintain temperature for
Versapak transport bag for blood, small (BLTD1) 2 x 0.5 liters of water 2 x 400g 1 x 250g 21°C
30°C
11 hrs 59 min
6 hrs 25 min
Versapak transport bag for blood, large (BLTD2) 6 x 0.5 liters of water 2 x 750g 2 x 250g 21°C
30°C
> 24 hours
5 hrs 02 min
Versapak insulated medical transport bag, small (PYTB1) 4 x 0.5 liters of water 3 x 400g 1 x 250g 21°C
30°C
6 hrs 53 min
4 hrs 07 min
Versapak insulated medical transport bag, medium (PYTB2) 12 x 0.5 liters of water 3 x 750g 1 x 650g 21°C
30°C
22 hrs 11 min
9 hrs 41 min
Versapak insulated medical transport bag, large (PYTB3) 16 x 0.5 liters of water 5 x 750g 2 x 250g 21°C
30°C
> 24 hours
12 hrs 39 min
Versapak transport bag for human milk (PYBHM) 8 x 0.5 liters of water 2 x 750g 1 x 250g 21°C
30°C
> 24 hours
7 hrs 50 min
Versapak padded bag for medication (CCBXPHCY) 18 x 0.5 liters of water 3 x 750g 1 x 650g 21°C > 24 hours

*All tests were initiated with cooling elements (cold packs and ICECATCH) prepared to -18 °C for 24 hours. Thermal barriers were prepared to 4 °C. The complete test report can be found here.

The above information is for guidance only. Changes can be made depending on the application and the desired result.

In addition, we have tested our transport bags for blood with 20 °C PCM under two environmental conditions. The following tables provide an overview of the performance:

Versapak transport bag for blood with 20 °C PCM unit tested to maintain a temperature of 15-25 °C

Ambient temperature 10 °C

Article Sample material (liter) (prepared to +4 °C) PCM PCM preparation (24 hours) Use Limit temperature Maintain temperature for
Versapak transport bag for blood, small (BLTD1) 2 x 0.5 liters of water 1 x 900g PCM 20°C 25°C Content then PCM 15°C > 24 hours
Versapak transport bag for blood, large (BLTD2) 6 x 0.5 liter water 1 x 900g PCM 20°C 25°C Content then PCM 15°C 15 hrs 29 min

Ambient temperature 30 °C

Article Sample material (liter) (prepared to +4 °C) PCM PCM preparation (24 hours) Use Limit temperature Maintain temperature for
Versapak transport bag for blood, small (BLTD1) 2 x 0.5 liters of water 1 x 900g PCM 20°C 10°C Contents then PCM 25°C > 24 hours
Versapak transport bag for blood, large (BLTD2) 6 x 0.5 liters of water 1 x 900g PCM 20°C 10°C Contents then PCM 25°C > 24 hours

*All tests started with a PCM battery prepared at an ambient temperature of 10°C to 25°C for 24 hours and a PCM battery prepared at an ambient temperature of 30°C to 10°C for 24 hours. The complete test report can be found here.

The above information is for guidance only. Changes can be made depending on the application and the desired result.